本文へ移動

論文 ·日本語 ·未確認

Validity of ultrasound muscle thickness measurements for predicting leg skeletal muscle mass in healthy Japanese middle-aged and older individuals

Yohei Takai Megumi Ohta Ryota Akagi Emika Kato Taku Wakahara Yasuo Kawakami Tetsuo Fukunaga Hiroaki Kanehisa

刊行年
2013-09-25
収録
『Journal of PHYSIOLOGICAL ANTHROPOLOGY』 32(1) pp. 12-12
出版
BioMed Central
言語
英語
OpenAlex
W2103782982
DOI
10.1186/1880-6805-32-12
PubMed
24067065
MAG
2103782982
ISSN
1880-6791
URL
https://jphysiolanthropol.biomedcentral.com/counter/pdf/10.1186/1880-6805-32-12

要旨

BACKGROUND: The skeletal muscle mass of the lower limb plays a role in its mobility during daily life. From the perspective of physical resources, leg muscle mass dominantly decreases after the end of the fifth decade. Therefore, an accurate estimate of the muscle mass is important for the middle-aged and older population. The present study aimed to clarify the validity of ultrasound muscle thickness (MT) measurements for predicting leg skeletal muscle mass (SM) in the healthy Japanese middle-aged and older population. FINDINGS: MTs at four sites of the lower limb and the bone-free lean tissue mass (LTM) of the right leg were determined using brightness-mode ultrasonography and dual-energy X-ray absorptiometry (DXA), respectively, in 44 women and 33 men, 52- to 78-years old. LTM was used as a representative variable of leg skeletal muscle mass. In the model-development group (30 women and 22 men), regression analysis produced an equation with R2 and standard error of the estimate (SEE) of 0.958 and 0.3 kg, respectively: LTM (kg) = 0.01464 × (MTSUM×L) (cm2) - 2.767, where MTSUM is the sum of the product of MTs at four sites, and L is length of segment where MT is determined. The estimated LTM (7.0 ± 1.7 kg) did not significantly differ from the measured LTM (7.0 ± 1.7 kg), without a significant systematic error on a Bland-Altman plot. The application of this equation for the cross-validation group (14 women and 11 men) did not yield a significant difference between the measured (7.2 ± 1.6 kg) or estimated (7.2 ± 1.6 kg) LTM and systematic error. CONCLUSION: The developed prediction equation may be useful for estimating the lean tissue mass of the lower extremity for the healthy Japanese middle-aged and older population.

主題

この書誌の出所

  • openalex— W2103782982(2026-08-14取得)

引用

Yohei Takai・Megumi Ohta・Ryota Akagi・Emika Kato・Taku Wakahara・Yasuo Kawakami・Tetsuo Fukunaga・Hiroaki Kanehisa(2013-09-25) Validity of ultrasound muscle thickness measurements for predicting leg skeletal muscle mass in healthy Japanese middle-aged and older individuals 『Journal of PHYSIOLOGICAL ANTHROPOLOGY』 32(1) pp. 12-12 BioMed Central

Takai2013ValidityUltrasoundMuscle
書誌 67,320件 語別索引 17,251件 資源 113件 研究者 303名 JSON